How can a hosting company offer you a guaranteed service level (SLA) when they’re not in control of their infrastructure? Because we design, build and manage our own datacentres, we’re in full control, and can confidently stand behind our SLAs.
We put significant time, effort and money into making sure our datacentres are up to scratch, with resilient power, air conditioning and security in-place. Make sure you come for a datacentre tour to see for yourself.
Watch out for other hosting companies pretending to have their own datacentre, when in fact they’re simply taking space in someone else’s.
Unlike many other providers, we're happy to show you around our dedicated hosting facilities. Come and see for yourself how we offer the highest levels of uptime and service. Click here to book a datacentre tour today.
We own and operate two primary facilities in Manchester, along with a third disaster recovery/backup facility.
Reynolds House and Turing House are sister buildings located on the Manchester Technopark on the periphery of Manchester City Centre.
These two buildings comprise our primary hosting facilities. We have long-term leases on these spaces, and have fitted out the hosting space to our own specifications. We're in complete control and are not resellers of other companies' datacentre space.
Our Rack Space customers are housed in Reynolds House, whereas all our shared colocation, dedicated and virtual hosting is housed in Turing House.
They say a picture speaks a thousand words, so instead of boring your with pages of detail, see the exciting datacentre equipment for yourself with our picture tour below. Even better idea - why not come for a datacentre tour?

Reynolds House is supplied by two diverse 6.6KV feeds from a the national grid. Two 2MW Generators with at least 7 days supply of fuel, provide us with full capability to sustain long power outages.

Our APC Infrastruxure UPS units, in n+1 mode provide us with power to sustain load until the generator starts up as well as ensuring a clean electrical supply.

N+1 Air conditioning is provided by under floor cooling, the air flow directed appropriately by grilles in the floor. The capacity of the equipment is such that a failure of one unit can be handled by the other units.

A full VESDA system that provides early detection of smoke is in place so that any potential fire is detected before it can develop. In the extremely unlikely event that a fire does develop a FM200 gas fire suppression system is triggered.

The facility is based on Manchester TechnoPark which has security staff on site 24/7 with offsite backup to deal with any major event. CCTV cameras (both internal and external), motion detection and a key fob access system ensures a high level of security with multiple layers of defence.
If you'd like specific technical specifications of our Manchester datacentre facilities, please find links to specification PDF files below: